- Contact Person : Ms. gao katherine
- Company Name : Xinxiang New Future Electric Co., Ltd.
- Tel : 0086-373-5010901
- Fax : 0086-373-5010903
- Address : Henan,xinixang,high-tech business incubator, chuangye road ,development zone ,xinxiang,henan province
- Country/Region : China
- Zip : 453003
NFC-2000Q Intelligent Power Distribution Monitor Terminal
Products Characteristic
1)more functions and high precision
Distribution intelligent monitoring terminal has strong data collect and disposal function and it can monitor dozens of (even hundreds )electric degree, at the same time ,it has 3-phase 4-wires voltage ,current harmonic real-time analysis of 3-19 times , electrical energy pulse output ,over electrical degree to alarm ,the most value record statistics, record 15minuts gap a kind of measuring quantity of electricity, data memory 3 months.
2)Communication grope web has strong function .
The communication function of distribution intelligent monitoring terminal is very strong .It has two ways light and electric separate RS-485/RS-232 gorge line one and RS-485 gorge line two .It support open way’s gorge communication pact and user can select different communication ways according to yourself need .The communication method can select UTP ,Coaxial Cable ,Data Radio and GPRS and it can compose high and economic electric monitor web with other monitor unit.
Display and operate easy
Distribution intelligent terminal monitor sampling 128*64 point LCD display and film button and maybe through button to select display measuring parameter or setting all of parameter. All of setting parameter in the meter of not lose memory .If power cut ,the data will not lost ,otherwise user can use homologous system parameter setting to set software and through the communication to parameter setting.
4)Installation convenient and nimble
Distribution intelligent terminal monitor has two ways of installation of embedded chips and wall hanging chips , it can satisfy the request of different scene.
5)High safety
Distribution intelligent terminal monitor select a kind of anti-high jamming software /hardware step, it can safety and reliability to operate in strong magnetic field area and the reliability is so high.
Technology parameter:
Environment requirement :
High above sea level:≤2500m
Working temperature:-20°C~+60°C Store temperature : -25°C~+70°C
Surrounding hasn’t medium of corrosive gas, electric dust , inflammable and explosive. There are hasn’t knock cold and sleet corrode in installation place.
Working power : 220V±20% (A type) 85V~265V(B type )
Weight :1.5Kg
Measuring signal : split phase
Measuring method: AC sampling
Measuring voltage :59v~280v Measuring current :0~5 A
Measuring power factory : lag0.200~ a head 0.200
Measuring harmonic :digital display
Measuring active power :0~999.9Kw(split phase)
Measuring reactive power :0~999.9Kvar(split phase)
Measuring active electric degree :0~999999.99Kwh
Measuring reactive electric degree: 0~999999.99Kvarh
Input/output signal:
Reactive compensation output:12v 30mA/branch
The quantity of on/off output:12v 30mA/branch♣(need out delay)
The quantity of on/off input :main point output (needn’t out delay) ♣
Temperature quantity input:PT100
Alarm output :250v 5A DELAY MAIN POINT
Communication interface data:
RS-485
Communication interface 1: using in remote terminal data select
Method:RS-485/RS-232(to select use front panel bouncing pin)
Brand rate :1200,2400,4800,9600,38400
Data post:8 data post
Parity bit: can setting
Stop spot:1 stop spot
Communication interface 2: using on terminal and other intelligent equipment interface ♣
Method : RS-485
Brand rate:1200,2400,4800,9600,38400
Data post:8 data post
Parity bit: can setting
Stop spot:1 stop spot
Measuring accuracy:
Voltage : ±0.5% Power : ±1.0%
Current ±0.5% Frequency: ±0.5%
Power factory: ±1.0% Electric quantity: ±1.0%
Above data get for after 10min and within 1 year current .
Setting data:
Voltage upper limit: 240v~275v Step-length:5v
Voltage lower limit: 175v~200v Step-length:5v
Goal power factory : 0.90~1.00 Step-length:0.01
Current transformer ratio : 1~1200
Capacitor switching delay time :20mS~300S
Harmonic voltage setting data: 5%~50% Step-length:0.5%
Tlock:0.5~1.2 Step-length:0.1
Zero sequence current :5%~50% Step-length:5%
Attention: “♣” is only Embedded structure product has the function .NFC-2000Q Intelligent Power Distribution Monitor Terminal